Skip to content
APEX TECHNICAL

ORIGINAL SOURCE CONTENT · FDB-0025

validation_registry.csv

The text below is original source material, not a translated website interface or empirical validation claim.

SHA-256 9a6b88d7d4bcbadb90b88b4376ebaa46145e40522e49d855de172dc53e8946a6

Validation_ID,Claim_ID,Validation_Requirement,Validation_Type
VAL-C-000259,CLM-C-000259,"Document coordinate definitions, response quantity and units, force and motion transducer models, sensitivities, calibration status, environmental limits, signal conditioning, and the driving-point or transfer measurement relationship.",DOCUMENTATION_REQUIREMENT
VAL-C-000260,CLM-C-000260,"Define the test article, support condition, exciter attachment, input point and axis, force transducer, response grid, frequency band, excitation levels, calibration status, and retained force-response records.",TEST_REQUIREMENT
VAL-C-000261,CLM-C-000261,"Create a coordinate and direction map, justify sensor locations against anticipated deformation patterns, measure repeatable force-response data, review observability and mode-shape consistency, and record unmeasured regions.",MEASUREMENT_REQUIREMENT
VAL-C-000262,CLM-C-000262,"Issue a controlled configuration list, weigh installed and omitted items, define the modal bandwidth and target modes, justify any mass or dynamic simulators, and retain a configuration deviation assessment with the test report.",DOCUMENTATION_REQUIREMENT
VAL-C-000263,CLM-C-000263,"Repeat selected inputs at multiple force levels, conduct reciprocal checks where applicable, retain force and response spectra, estimate damping for each accepted mode, flag level-dependent parameters, and approve the linear operating range.",VERIFICATION_REQUIREMENT
VAL-C-000264,CLM-C-000264,"Define and measure or justify the input time history, sampling interval, duration, coordinate system, model version, boundary conditions, damping representation, retained modes, output quantities, and uncertainty review.",MODEL_CORRELATION_REQUIREMENT
VAL-C-000265,CLM-C-000265,"Classify each input as deterministic or random, retain time histories or spectral-density records as applicable, state averaging and statistical rules, verify units, and keep the two result types separately traceable.",DOCUMENTATION_REQUIREMENT
VAL-C-000266,CLM-C-000266,"Define restraint or suspension geometry and stiffness, measure motion on both sides of the boundary where practical, document added masses and cables, measure test mass and center of gravity, and repeat a representative input after setup changes.",MEASUREMENT_REQUIREMENT
VAL-C-000267,CLM-C-000267,"Calibrate force and response channels, define coordinate signs, acquire synchronized force and response time histories, compute the declared FRF with retained processing settings, and label exploratory results separately from accepted measurements.",MEASUREMENT_REQUIREMENT
VAL-C-000268,CLM-C-000268,"Set the target frequency band, select and document impactor and tip, inspect force spectra and time records, apply anti-alias filtering, define sample rate and windows, reject overloads and double hits, and record averaging and repeatability.",VERIFICATION_REQUIREMENT
VAL-C-000269,CLM-C-000269,"Record whether signals are deterministic or random and transient or continuous, document transforms, scaling, normalization, units, sample rate, record duration, and software version, and reproduce selected calculations from retained raw data.",DOCUMENTATION_REQUIREMENT
VAL-C-000270,CLM-C-000270,"Tag every dataset as measured or simulated, retain model and acquisition versions, align coordinates and units, define frequency matching and uncertainty rules, and document residuals without replacing test data with model output.",MODEL_CORRELATION_REQUIREMENT
VAL-C-000271,CLM-C-000271,"Retain raw time records, window type and parameters for every channel, acquisition duration, sampling rate, frequency resolution, overlap and averaging settings, and compare at least one representative record under justified alternative windows.",VERIFICATION_REQUIREMENT
VAL-C-000272,CLM-C-000272,"Test representative material and specimen configurations, record dimensions, temperature, frequency, excitation and response, base-beam properties, calculation route, replicate scatter, and the intended model-input mapping.",TEST_REQUIREMENT
VAL-C-000273,CLM-C-000273,"Verify response linearity over repeated excitation levels, measure layer and bond thicknesses, record adhesive and cure history, select the applicable specimen configuration, retain excluded modes, and quantify repeatability.",VERIFICATION_REQUIREMENT
VAL-C-000274,CLM-C-000274,"Document deformation mode, strain amplitude, frequency, temperature, specimen geometry and material state, verify linear response, and correlate any material-property model to separate structural modal tests.",MODEL_CORRELATION_REQUIREMENT
VAL-C-000275,CLM-C-000275,"Use matched material states and environmental conditions, identify deformation mode and stress distribution, verify homogeneity assumptions, quantify uncertainty, and retain separate values where equivalence is not demonstrated.",VERIFICATION_REQUIREMENT
VAL-C-000276,CLM-C-000276,"Record specimen materials, layer sequence and dimensions, conditioning, temperature, frequency range, excitation and response method, resonance-curve reduction, repeatability, and explicit material-versus-structure classification.",DOCUMENTATION_REQUIREMENT
VAL-C-000277,CLM-C-000277,"Retain the calibrated acceleration time history, units, sample interval, record duration, axis, preprocessing, SRS type, oscillator frequencies, assumed damping values, algorithm version, and output units.",DOCUMENTATION_REQUIREMENT
VAL-C-000278,CLM-C-000278,"Define the required oscillator band, choose sampling and anti-alias controls, verify filter coefficients against a reference case, compare results after controlled resampling, and retain software and precision settings.",VERIFICATION_REQUIREMENT
VAL-C-000279,CLM-C-000279,"Select a calibration covering the expected pulse duration and amplitude, document reference transducer traceability, mounting, conditioning and digitization, check overload and zero shift, and include calibration uncertainty with measured peaks.",CALIBRATION_REQUIREMENT
VAL-C-000280,CLM-C-000280,"Maintain separate calibration certificates and checks for acceleration and dynamic-force channels, verify applicable quantity and range, perform pretest channel checks, and reject certificates outside the instrument or method scope.",CALIBRATION_REQUIREMENT
VAL-C-000281,CLM-C-000281,"Create a controlled mass-property record with article identifier, configuration, measurement date, method, axes and origin, mass, center of gravity and inertia terms as applicable, uncertainty, approver, and downstream model or test references.",DOCUMENTATION_REQUIREMENT
VAL-C-000282,CLM-C-000282,"Define estimate and measured-data status, set change thresholds, reweigh or remeasure after relevant configuration changes, retain deltas and uncertainty, and approve model or test reuse against the current configuration.",VERIFICATION_REQUIREMENT
VAL-C-000283,CLM-C-000283,"Define body axes and origin, measure mass and center of gravity, qualify the selected inertia method with reference artifacts, apply fixture and support corrections, repeat orientations, calculate uncertainty, and retain raw periods, loads, and geometry.",MEASUREMENT_REQUIREMENT
VAL-C-000284,CLM-C-000284,"Assign controlled status values, require raw data and calibration records before marking a measurement executed, require independent review before acceptance, and prevent planned values from populating validated dynamic-model inputs.",DOCUMENTATION_REQUIREMENT
VAL-C-000285,CLM-C-000285,"Document sensor model and mass, mounting surface preparation, attachment method, orientation, torque where applicable, cable restraint, mounting resonance or usable bandwidth, and a post-installation channel check.",VERIFICATION_REQUIREMENT
VAL-C-000286,CLM-C-000286,"Create a channel checklist covering axis alignment, transverse sensitivity, base bending, cable routing and restraint, temperature, field exposure, connector security, torque, noise floor, and pretest and post-test functional checks.",VERIFICATION_REQUIREMENT
VAL-C-000287,CLM-C-000287,"Retain reference and test transducer certificates, serial numbers, sensitivities versus frequency, mounting and conditioning, comparison setup, date, environmental conditions, uncertainty, and calibration due status.",CALIBRATION_REQUIREMENT
VAL-C-000288,CLM-C-000288,"Build an uncertainty budget by frequency, include reference sensitivity, repeatability, mounting, alignment, conditioning, environmental and readout effects, run a check standard, and propagate accepted uncertainty to reported response quantities.",CALIBRATION_REQUIREMENT
Download exact original