Skip to content
APEX TECHNICAL

G-B10 REV0 · ORIGINAL SOURCE VALUE

CMP-G-B10-0000008

Registry: architecture_comparison_matrix. Original field names and values are displayed without translation or reinterpretation.

absolute_change
0.0
baseline_value
100000.0
baseline_variant_id
VAR-G-B10-000001
comparison_category
FATIGUE_TENDENCY
comparison_id
CMP-G-B10-0000008
comparison_interpretation
NO_MODELLED_DIFFERENCE_BECAUSE_FATIGUE_INPUTS_WERE_HELD_CONSTANT; NOT EVIDENCE OF EQUAL DURABILITY
comparison_metric
Cycle projection at normalized load 0.50
configuration_id
AER-FC002-16-T700-PP-SHP
data_class
MODEL_DERIVED
empirical_status
NOT_EMPIRICAL
evaluation_status
INSUFFICIENT_BASIS_FOR_ARCHITECTURE_DISCRIMINATION
failure_mode_exposure
UNQUANTIFIED_GB8_HYPOTHESES; NOT_OBSERVED
fatigue_tendency
UNCHANGED_BY_GB9_ARCHITECTURE_SCENARIOS; VERY_LOW_CALIBRATION_CONFIDENCE
limitation
Not a service-life, durability or fatigue-allowable claim. Requires controlled cyclic calibration before engineering use.
linked_gb8_dependency_ids
DEP-G-B8-000017|DEP-G-B8-000036|DEP-G-B8-000055|DEP-G-B8-000074|DEP-G-B8-000093|DEP-G-B8-000112|DEP-G-B8-000131|DEP-G-B8-000150|DEP-G-B8-000169|DEP-G-B8-000188|DEP-G-B8-000207|DEP-G-B8-000226|DEP-G-B8-000245|DEP-G-B8-000264|DEP-G-B8-000283|DEP-G-B8-000302|DEP-G-B8-000305|DEP-G-B8-000306|DEP-G-B8-000307|DEP-G-B8-000308|DEP-G-B8-000309|DEP-G-B8-000310|DEP-G-B8-000311|DEP-G-B8-000312|DEP-G-B8-000313|DEP-G-B8-000314|DEP-G-B8-000315|DEP-G-B8-000316|DEP-G-B8-000317|DEP-G-B8-000318|DEP-G-B8-000319|DEP-G-B8-000320|DEP-G-B8-000321|DEP-G-B8-000322|DEP-G-B8-000323|DEP-G-B8-000340|DEP-G-B8-000359
linked_gb8_failure_interaction_ids
FMI-G-B8-000001|FMI-G-B8-000002|FMI-G-B8-000003|FMI-G-B8-000004|FMI-G-B8-000005|FMI-G-B8-000006|FMI-G-B8-000007|FMI-G-B8-000008|FMI-G-B8-000009|FMI-G-B8-000010
linked_gb8_profile_statement_ids
PROF-G-B8-000001|PROF-G-B8-000002|PROF-G-B8-000003|PROF-G-B8-000004|PROF-G-B8-000010|PROF-G-B8-000011|PROF-G-B8-000012|PROF-G-B8-000013|PROF-G-B8-000014|PROF-G-B8-000015|PROF-G-B8-000016|PROF-G-B8-000017
linked_gb8_uncertainty_ids
UPROP-G-B8-000001|UPROP-G-B8-000002|UPROP-G-B8-000003|UPROP-G-B8-000004|UPROP-G-B8-000005|UPROP-G-B8-000006|UPROP-G-B8-000007|UPROP-G-B8-000008|UPROP-G-B8-000009|UPROP-G-B8-000010
manufacturing_sensitivity
Baseline manufacturing capability, tolerance stack, defect rate and process limits are NOT_ESTABLISHED in FDB-0025.
model_validity
VALID_WITHIN_FROZEN_INPUT_BOUNDS
percent_change
0.0
physical_validation_status
NOT_COMPLETED
prediction_id
PRED-G-B7-000017
relationship_label
MODEL-DERIVED / NOT EMPIRICAL
source_gb7_model_id
MODEL-G-B7-000005
source_gb9_output_id
OPTOUT-G-B9-0000017
source_gb9_scenario_id
OPTSCN-G-B9-000001
uncertainty_level
HIGH_BASELINE_MODEL_UNCERTAINTY
unit
cycles
value_type
NUMERIC_MODEL_OUTPUT
variant_id
VAR-G-B10-000001
variant_value
100000.0

Identifiers mentioned in source fields

These are search links, not inferred engineering relationships.

Provenance

archiveSha256
473b9d23605d8e35043a02e7215afd86897c101e48f81c75d1d7b7cc39343e13
virtual_path
!/STAGEG_B10_VARIANT_ARCHITECTURE_COMPARISON_REV0/architecture_comparison_matrix.csv
source_file_sha256
db019f7f520aa7d258983c20e279219cb4c40e56595c162c302f2b46089fa7b6
source_locator
csv:row:8
fields_sha256
9c8b1455d442b1601c38780d4cf68eed26c6a8cbbc60c5c9cb0769f23b42ed0f
source_version
G-B10 REV0