Skip to content
APEX TECHNICAL

G-B9 REV0 · ORIGINAL SOURCE VALUE

OPTOUT-G-B9-0000019

Registry: STAGEG_B9_ENGINEERING_SENSITIVITY_AND_DESIGN_OPTIMIZATION__Scenario_Outputs. Original field names and values are displayed without translation or reinterpretation.

A
OPTOUT-G-B9-0000019
B
OPTSCN-G-B9-000001
C
PRED-G-B7-000019
D
Normalized stiffness retention at 100000 cycles
E
0.93
F
ratio
G
0.93
H
0
I
0
J
MODEL-G-B7-000005
K
{"beam_width_mm":"50","core_cell_size_mm":"9","core_compression_strength_mpa":"1.565","core_density_kg_m3":"72","core_shear_modulus_mpa":"14.5","core_shear_strength_mpa":"0.495","core_shear_stress_mpa":"0.25","core_thickness_mm":"15","face_architecture_factor":"0.45","face_thickness_mm":"0.5","fatigue_anchor_cycles":"100000","fatigue_exponent":"8","process_retention_factor":"0.88","stiffness_retention_ratio":"0.93","strength_transfer_factor":"0.35","support_span_mm":"300","total_thickness_mm":"16"}
L
FDB-0025->PRED-G-B7-000019->MODEL-G-B7-000005->OPTSCN-G-B9-000001
M
BASELINE_REFERENCE
N
UPROP-G-B8-000008|UPROP-G-B8-000009|UPROP-G-B8-000010
O
VALID_WITHIN_FROZEN_INPUT_BOUNDS
P
EVALUATED
R
AER-FC002-16-T700-PP-SHP
S
PREDICTED
T
MODEL-DERIVED / NOT EMPIRICAL
U
NOT_EMPIRICAL
V
NOT_PERFORMED
W
NOT_PROMOTED
X
OPEN
Y
Not a service-life, durability or fatigue-allowable claim. Requires controlled cyclic calibration before engineering use.

Identifiers mentioned in source fields

These are search links, not inferred engineering relationships.

Provenance

archiveSha256
24b3b7accd68728d0c0e35222da86bf55e015cc4e2369d97f455399a1662f8cf
virtual_path
!/STAGEG_B9_ENGINEERING_SENSITIVITY_AND_DESIGN_OPTIMIZATION_REV0/STAGEG_B9_ENGINEERING_SENSITIVITY_AND_DESIGN_OPTIMIZATION.xlsx
source_file_sha256
fedd72dfc37d0a12ad3e7118ab6bebf8bb8c466136ec668b83c779a6698c255c
source_locator
xlsx:sheet:6:Scenario Outputs:row:20
fields_sha256
66f59e9642fb6e69e7340430c8830ed3c3069823f6252b6f872ec7271bfe791d
source_version
G-B9 REV0