Skip to content
APEX TECHNICAL

G-C1 REV0 · ORIGINAL SOURCE VALUE

CPRED-G-C1-000073

Registry: STAGEG_C1_NEW_PADDLE_ENGINEERING_DESIGN_GENERATION__Predictions. Original field names and values are displayed without translation or reinterpretation.

A
CPRED-G-C1-000073
AA
NOT_EMPIRICAL
AB
NOT_COMPLETED
B
DESIGN-G-C1-000006
C
CMP-G-B10-0000086
D
PRED-G-B7-000017
E
FATIGUE_MODEL_OUTPUT_WITH_INSUFFICIENT_DISCRIMINATION_BASIS
F
Cycle projection at normalized load 0.50
G
100000
H
cycles
I
100000
J
0
K
0
L
Changed parameters: core_cell_size_mm|core_compression_strength_mpa|core_density_kg_m3|core_shear_modulus_mpa|core_shear_strength_mpa|core_thickness_mm|face_architecture_factor|face_thickness_mm|process_retention_factor; manufacturing sensitivity: LEV-G-B8-000001: Fiber alignment, layup, consolidation and defect control in the T700 faces. | LEV-G-B8-000002: Semi-hot-press temperature, pressure, dwell and consolidation control. | LEV-G-B8-000003: Ply count/gauge, resin content, mass balance and bondline/edge integration. | LEV-G-B8-000004: PP honeycomb grade, cell geometry, orientation and supplier-lot verification. | LEV-G-B8-000005: PP honeycomb grade/cell-wall state plus face-core bond and indentation resistance. | LEV-G-B8-000006: Core procurement, machining/tolerance, mass and dimensional control.
M
NO_MODELLED_DIFFERENCE_BECAUSE_FATIGUE_INPUTS_WERE_HELD_CONSTANT; NOT EVIDENCE OF EQUAL DURABILITY
N
UNQUANTIFIED_GB8_HYPOTHESES; NOT_OBSERVED
O
UNCHANGED_BY_GB9_ARCHITECTURE_SCENARIOS; VERY_LOW_CALIBRATION_CONFIDENCE
P
VERY_HIGH
Q
G-B10 uncertainty level VERY_HIGH; linked paths UPROP-G-B8-000001|UPROP-G-B8-000002|UPROP-G-B8-000003|UPROP-G-B8-000004|UPROP-G-B8-000005|UPROP-G-B8-000006|UPROP-G-B8-000007|UPROP-G-B8-000009|UPROP-G-B8-000010
R
VALID_WITHIN_FROZEN_INPUT_BOUNDS
S
INSUFFICIENT_BASIS_FOR_ARCHITECTURE_DISCRIMINATION
T
OPTSCN-G-B9-000041
U
FMI-G-B8-000001|FMI-G-B8-000002|FMI-G-B8-000003|FMI-G-B8-000004|FMI-G-B8-000005|FMI-G-B8-000006|FMI-G-B8-000007|FMI-G-B8-000008|FMI-G-B8-000009|FMI-G-B8-000010
V
UPROP-G-B8-000001|UPROP-G-B8-000002|UPROP-G-B8-000003|UPROP-G-B8-000004|UPROP-G-B8-000005|UPROP-G-B8-000006|UPROP-G-B8-000007|UPROP-G-B8-000009|UPROP-G-B8-000010
W
Not a service-life, durability or fatigue-allowable claim. Requires controlled cyclic calibration before engineering use.
X
AER-FC002-16-T700-PP-SHP
Y
MODEL_DERIVED
Z
MODEL-DERIVED / NOT EMPIRICAL

Identifiers mentioned in source fields

These are search links, not inferred engineering relationships.

Provenance

archiveSha256
1e98756b489c9f76565bcb4e2d0e8bffcf3565f351d83b9211cd92220d76e85d
virtual_path
!/STAGEG_C1_NEW_PADDLE_ENGINEERING_DESIGN_GENERATION_REV0/STAGEG_C1_NEW_PADDLE_ENGINEERING_DESIGN_GENERATION.xlsx
source_file_sha256
8ebe9f0b4a369ae32a8de2e4d52a42e28985fde3a6d1c33b7c4f9e19be35e3d3
source_locator
xlsx:sheet:4:Predictions:row:74
fields_sha256
3eb484f5f9844e70873bbeb73327b3af0d3775a7a87393a08bbca84fe2f60e20
source_version